SPECIFICATIONS
EXHAUST FANS
AK927
70 CFM/3.5 SONES @ 0.10" wg.
HVI CERTIFIED 120 Volts, 4.6 amps, 60 hz.
Grill
White, polymeric grill (flame retardant ABS UL rated 94-5V)
secured in place with torsion springs; easily removed if
neccessary, dimensions
- 16
1
/
2
" x 10".
Blower Wheel
One piece polymeric wheel, 3
7
/
8
" diameter, 2
1
/
2
" wide with 21 fins.
Motor
Heavy duty, plug in 2 pole motor. Life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 0.90 amps.
Fan Housing
23 gauge galvanized steel housing. Dimensions 13
7
/
8
" x 8" x 5
7
/
8
".
Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
Ventilating Area
For bathrooms up to 70 sq. ft.
Lamping Information
2 - 250 watt maximum, type R40 bulb, medium base, 1700 Btu.
CUL/HVI - TYPE IC RATED
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048
Updated 1-06Specifications subject to change without notice.
Unit Mounting
The housing will mount in ceilings with at least 6" of clearance
and through drywall thickness up to
3
/
4
", with a rough-in opening
of 13
7
/
8
" x 8". Rated for ceilings insulated to R-40. The housing
will mount between 16" on center joists, using the 4 supplied
housing mounting rails.
Single Pack Shipping Info
Box Dim: 18" x 11
1
/
2
" x 7
3
/
4
"
UPC: 0-8316227011-5
Shipping Weight: 9 lbs.
CUS
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
PERFORMANCE
HVI Sones Fan Speed Power
Static Pressure (inches of w.g.) @ .1 SP RPM Watts
0 0.05 0.1 0.125 0.15 0.2 0.25 0.3
Air Flow - CFM
Air-King exhaust fans are tested by the Air Movement and Control Association (AMCA) in accordance with HVI test standard 916, (Air Flow Test Standard) and HVI test standard
915 (Procedure For Loudness Rating Of Residential Fan Products). The Performance results are certified and verified by the Home Ventilating Institute (HVI).